Leave Your Message

Ring Main Unit Assembly Production Line

A ring main unit assembly production line is an industrial production system specifically designed for manufacturing, assembling, and testing ring main units (RMU). As core equipment in distribution networks, RMU are responsible for functions such as power distribution, fault isolation, and circuit protection. The production line must meet stringent requirements for high precision, high reliability, and flexible customization.

    Description

    Material supply system

    - Intelligent warehousing: use stereoscopic warehouse or automated shelving cabinets to store core components such as cabinet bodies, switches, and insulators.

    - Logistics distribution: AGV(Automated Guided Vehicles) or suspended chain conveyance systems ensure precise material delivery.

    - Intelligent picking: utilizes RFID or visual recognition technology to automatically match materials with production orders.

    Cabinet Pre-treatment Section

    • Sheet Metal Processing: Laser cutting/bending center completes precise cabinet shaping.

    • Surface Treatment: Automated spray line achieves corrosion protection (such as epoxy powder spraying).

    • Leak Detection: Helium mass spectrometer leak detector performs micro-leak detection on pressurized cabinets (accuracy up to 10^-6 mbar·L/s).

    Core assembly module

    - Switchgear module: The robotic arm automatically assembles vacuum interrupters, with a torque control system ensuring bolt tightening precision (±3%).

    - Busbar system: CNC busbar processing machines achieve ±0.1mm bending accuracy and automatically wrap insulating materials.

    - Secondary system: Automated crimping equipment completes the assembly of control wiring harnesses, and the test bench immediately detects circuit impedance.

    Testing and verification system

    - Mechanical characteristic testing: High-speed cameras record the opening and closing process of switches (time resolution 0.1 ms).

    - Electrical tests: 200 kV power frequency withstand voltage equipment + Ultra-high frequency partial discharge detection (sensitivity 1 pC).

    - System integration testing: Automatic injection of fault current to verify the accuracy of protective actions.

    The Features

    A 单相RMU
    C 绝缘RMU
    B 绝缘 RMU

    Hybrid production model

    • Utilizes a layout of 'automation islands + manual workstations', with key processes such as busbar processing fully automated (cycle time 0.8 minutes per piece), while complex assembly retains points for manual intervention

    Digital twin applications:

    • Optimize assembly processes through 3D simulation (such as virtual validation of mechanical linkages and fitment), ensuring actual assembly errors are controlled within ±0.05mm.

    Special environmental control

    • Establish a Class 10,000 clean room for insulator assembly, with temperature and humidity controlled at 23±2°C/45±5% RH. The SF6 handling area is equipped with a negative pressure exhaust system, achieving a gas recovery rate of over 99.9%.

    Full-process quality traceability

    Each cabinet generates a unique DNA code, recording over 200 production data points (including bolt torque curves, vacuum level change curves, etc.).

    Application Scenarios

    Ring Main Unit Assembly Production Line (14)
    01

    Urban Power Grid System 

    1. Distribution Substation/ Switching Station

    - Acts as a node device for 10kV-40.5kV distribution networks, facilitating power distribution and fault isolation.

    - Typical application: Smart ring network cabinets in urban underground conduits (integrated DTU for 'three remote' functions)- Technical specifications: Protection level IP67, short-circuit breaking capacity of 25kA.

    2. Cable Branch Box Upgrade

    - Replaces traditional cable branch boxes, featuring automatic fault location capabilities.

    - Case study: Singapore's 'Smart Grid' project uses fully insulated RMUs, reducing fault recovery time by 80%.

    new
    02

    New Energy Power Generation Field 

    1. Photovoltaic/Wind Power Collection System◦ 35kV ring main units used to collect inverter output current◦ Special requirements: salt mist corrosion resistance (C5 level), ability to operate at -40°C low temperatures

    2. Energy Storage Power Station

    ◦ Ring main protection system between battery clusters◦ Innovative application: Huawei's intelligent energy storage solution uses RMU equipped with 5G communication modules

    industry
    03

    Industrial Power Usage Scenarios 

    1. Power Supply for Industrial Parks

    ◦ Dual power source ring network cabinets ensure continuous power supply (MTBF > 100,000 hours)◦ Typical case: Tesla's Shanghai factory uses dual-bus RMU architecture

    2. Power Supply for Mines/Oilfields

    ◦ Explosion-proof design (Ex d IIC T4 standard)

    ◦ Vibration resistance requirement: Passed random vibration tests from 5 to 500 Hz

    sendinquiry